  agilent N7784B high speed polarization controller data sheet introduction the agilent N7784B polarization controller contains a high-speed polarization controller plus microcontroller- based driving circuitry. this unit can operate in various modes. as a polarization stabilizer , it provides a stable output state of polarization (sop) even with ? uctuations and drifts of the input sop as occurring for example through temperature drift and mechanical settling processes. the stabilized output signal is guided in a polarization main- taining ? ber (pmf). alternatively, an external electrical feedback signal can be provided for stabilizing the sop. as a synchronous scrambler , the device switches the sop of the output signal in a random (pseudo) way. switching of the sop occurs within a few microseconds. the sop is stable for a prede? ned time until it again switches to a new sop. an electrical trigger input can be used to synchronize the scrambler with external events. as an sop switch, the N7784B allows switching the internal waveplates to user de? nable angles with very high speed and repeatability. as traditional scrambler the N7784B varies the output sop smoothly in a random/pseudo random way. the unit does not contain any moving parts and there- fore is robust and withstands even rough environmental conditions. all above-mentioned applications of the N7784B are supported by a pc software package. pc-based application software comes with this instrument. other instrument drivers for various software interfaces are available. figure 1. N7784B-001 bench-top mainframe
2 agilent N7784B high speed pola rization controller data sheet laser interferogram N7784B high-speed polarization controller sensor application examples fiber optic based interferometers or coherent receiver schemes need polarization stabilization in order to avoid fading problems of the interference signal. these fading effects are caused by orthogonally polarized fractions of the light. the N7784B allows elimination of such effects by alignment of the signal polarization. the results obtained in re-circulating loop experiments depend heavily on the pmd and pdl properties of the loop. loop synchronous polarization scrambling schemes have proven to be necessary for generating results comparable to deployed systems. the N7784B is ideally suited to provide the synchronous scrambling capability in such experiments. in addition, the n7781b polarization analyzer provides the capability of monitoring the sop evolution on each round trip. figure 2. N7784B instrument setup figure 3. interferometry/coherent detection applications interferometry: polarization stabilization to maximize contrast ratio recirculating loop experiments: loop-synchronous polarization scrambling system test: polarization sensitivity analysis on link/transmission quality agilent N7784B instrument setup and application examples the instrument setup is shown in figure 1. if a scrambling or switching operation is desired, only ports i and ii are used. if the sop of the signal is stabilized and the signal is fed in a pmf, then port ii and port iii have to be connected by an smf. in this situation, the output signal is available on port iv. if an external feedback signal is available for stabilization, only ports i and ii are occupied. key bene? ts comprehensive polarization control and management capabilities covers s-, c- and l-band plus 1.3 m window (o-band) compact size standalone operation robust, no moving parts pc software package included polarization controller smf pmf smf pol splitter power in analog in pc input port i port iv port ii port iii pc output pbs input pbs output optical input gpib usb trigger in trigger out dsp based control electronics N7784B high speed polarization controller computer trigger tx unit ampli?er switch rx unit fiber loop pol contr figure 4. recirculating loop
3 agilent N7784B high speed pola rization controller data sheet table 1: speci? cations 1) N7784B polarization controller wavelength operating wavelength range 1260 nm ... 1640 nm wavelength range in stabilizer mode 2) 1520 nm ... 1580 nm polarization control and stabilization sop switching time (open-loop) < 10 s per at pmf output > 23 db stabilizer response time 3) (typical) 2 ms optical power insertion loss port i - port ii 4) insertion loss port iii - port iv 5) < 3.5 db (< 3.0 db, typ.) < 1.8 db (< 1.4 db, typ.) pdl port i - port ii (typical) < 0.2 db maximum safe input power port i: 20 dbm port iii: 3 dbm input power range in stabilizer mode port iii: -30 dbm ... 0 dbm 1) ambient temperature change max. 0.5c since normalization. speci? cation valid on day of calibration. 2) outside the stabilizer wavelength range, the per at pmf output may be degraded. 3) input power > -20 dbm. 4) for sop scrambling/switching, only ports i/ii are used. 5) valid for optimum input polarization at pbs input (port iii). add insertion loss of port i/ii and obtain total insertion los s for sop stabilizing mode.
www.agilent.com/? nd/emailupdates get the latest information on the products and applications you select. www.agilent.com/? nd/agilentdirect quickly choose and use your test equipment solutions with con? dence. agilent email updates agilent direc t www.agilent.com for more information on agilent technologies products, applications or services, please contact your local agilent office. the complete list is available at: www.agilent.com/find/contactus americas canada (877) 894-4414 latin america 305 269 7500 united states (800) 829-4444 asia paci? c australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 112 929 japan 81 426 56 7832 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 thailand 1 800 226 008 europe austria 0820 87 44 11 belgium 32 (0) 2 404 93 40 denmark 45 70 13 15 15 finland 358 (0) 10 855 2100 france 0825 010 700 germany 01805 24 6333* *0.14/minute ireland 1890 924 204 italy 39 02 92 60 8 484 netherlands 31 (0) 20 547 2111 spain 34 (91) 631 3300 sweden 0200-88 22 55 switzerland (french) 41 (21) 8113811(option 2) switzerland (german) 0800 80 53 53 (opt ion 1) united kingdom 44 (0) 118 9276201 other european countries: www.agilent.com/find/contactus revised: may 7, 2007 product speci? cations and descriptions in this document subject to change without notice. ? agilent technologies, inc. 2008 printed in usa, april 29, 2008 5989-8113en remove all doubt our repair and calibration services will get your equipment back to you, performing like new, when promised. you will get full value out of your agilent equipment throughout its lifetime. your equipment will be serviced by agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. you will always have the utmost con? dence in your measurements. agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. for more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt


▲Up To Search▲   

 
Price & Availability of N7784B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X